![]() You can help by choosing one of the links below to provide feedback about this product.We offer Unitronics V570 ColorOPLC. cCVSS Calculator,, web site last accessed June 23, 2016.įor any questions related to this report, please contact the CISA at:įor industrial control systems cybersecurity information: ĬISA continuously strives to improve its products and services.This web site will be active sometime after publication of this advisory. bNVD,, NIST uses this advisory to create the CVE web site report.aCWE-121: Stack-based Buffer Overflow,, web site last accessed June 23, 2016. ![]() Organizations observing any suspected malicious activity should follow their established internal procedures and report their findings to ICS-CERT for tracking and correlation against other incidents. Several recommended practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.Īdditional mitigation guidance and recommended practices are publicly available in the ICS‑CERT Technical Information Paper, ICS-TIP-12-146-01B-Targeted Cyber Intrusion Detection and Mitigation Strategies, that is available for download from the ICS-CERT web site ( ). ICS-CERT also provides a section for control systems security recommended practices on the ICS-CERT web page at. ICS-CERT reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. Also recognize that VPN is only as secure as the connected devices. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available.Locate control system networks and remote devices behind firewalls, and isolate them from the business network.Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. The latest version can be found on the Unitronics web site at the following location: Unitronics recommends that users upgrade to Visilogic Version 9.8.30 or later to mitigate this vulnerability. DIFFICULTYĪn attacker with a low skill would be able to exploit this vulnerability. No known public exploits specifically target this vulnerability. This vulnerability could be exploited remotely. A CVSS v3 base score of 7.3 has been calculated the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). The failure is caused by an attempt to copy into a fixed-length stack buffer without validating its length. VULNERABILITY CHARACTERIZATION VULNERABILITY OVERVIEW According to Unitronics, this product is used worldwide in multiple sectors. The affected product, Unitronics VisiLogic OPLC IDE, is an HMI and PLC application programming environment for Vision and SAMBA series controllers. Unitronics has offices in the United States and Israel. NCCIC/ICS-CERT recommends that organizations evaluate the impact of this vulnerability based on their operational environment, architecture, and product implementation. Impact to individual organizations depends on many factors that are unique to each organization. Unitronics reports that the vulnerability affects the following versions of VisiLogic:īy exploiting this vulnerability, an attacker may be able to remotely execute arbitrary code. Unitronics has produced a new version to mitigate this vulnerability. ![]() ZDI has identified a buffer overflow vulnerability discovered by Steven Seeley of Source Incite in Unitronics VisiLogic.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |